*Residential Service call's subject to $119.00 travel and diagnostic fee, Commercial Service call's subject to a $149.00 travel and diagnostic fee. Once diagnosed, necessary repairs will be quoted in accordance with standard flat rate repair price. Repair and quoted repair price may be accepted or declined by the customer at that time. Travel and Diagnostic fee will still apply in case customer declines repair. All calls are C.O.D. Overtime rates for Residential Service are $169.00, overtime rates for Commercial services are $179.00.  These rates are for services performed after normal business hours Monday through Friday 8am-4:30pm.
For most homeowners, any HVAC repair needs to be done in a timely manner. The longer you have to wait for AC repair, furnace repair, etc., the more difficult you will find it to maintain a comfortable temperature in your residence. Our experienced technicians will find the problem and complete air conditioner or furnace repair quickly. Instead of having to suffer through a cold winter or hot summer due to HVAC problems, contact Deljo Heating & Cooling.
If your AC doesn’t turn off when room temperature reaches the temperature set on the thermostat, the problem is generally occurring either at the thermostat or in the electrical system that runs the outside condensing unit. You can use the AC’s circuit breaker to shut off the unit, but that should not be a permanent solution—circuit breakers are not designed to be used like light switches.
Turn off the gas supply valve, typically located by your gas meter on the gas inlet pipe. Turn off the gas by rotating the valve one quarter turn with an adjustable wrench. When the gas is off,  the valve’s oblong stem points perpendicular to the inlet pipe. Then call your gas utility or the fire department from a remote location. Do not return to your home until you know it is safe.
As a Bryant Factory Authorized Dealer, Welzig Heating & Air consistently performs to strenuous standards of technical competence, business ethics, and customer approval.  Our team is NATE-certified, factory trained and regularly updated in progressive technology.  Equipped with leading edge equipment, tools, and a full inventory of genuine manufacturer’s replacement parts, we properly size and install new systems, accurately diagnose existing systems, and resolve the majority of issues right then and there.
AC units and thermostats have built-in delay features when they’re shut down and then repowered. The delay can be as long as 10 minutes. And, if you’ve subscribed to an energy-saving device from your local power utility, the unit can take even longer to reset. If you’ve installed the parts shown and reinstalled the disconnect block, repowered the circuit breaker, turned on the switch at the furnace, moved the thermostat to AC mode and lowered the temperature below the indoor temperature, and the unit doesn’t fire up after 30 minutes, it’s time to call a pro.

Furnace Repair Co

×