"LIFESAVER! Came right out to our home to save us from the heat. I called around 11 and they sent someone by the afternoon 1:30. Carlos fixed our AC on the spot! Very professional and knew what the issues were and fixed them all as fast as possible! Otherwise we would all be toast in this Texas Summer HEat. Thank you Carlos with Ruben's AC! Excellent service"
Vredevoogd Heating & Cooling Grand Rapids values each and every customer. Servicing or installing your HVAC system means establishing a service relationship with each homeowner. We promise to earn your trust with our consummate level of professionalism and expert service. We back our work with the strongest industry guarantees because we value your continued business.
The amount of time air duct cleaning takes can depend on how extensive your duct system is, how old your air ducts are, and whether they have ever been cleaned. On average, expect a standard size home (between 2,000 and 3,000 square feet) to take 2-5 hours for one to two technicians to clean. Here are the proper protocol and equipment you should expect from a professional duct cleaning service, as recommended by the Environmental Protection Agency:

High-efficiency condensing furnaces (90% AFUE and above) are a bit more complex than conventional furnaces. The main differences between a conventional and condensing furnace are the heat exchanger technology used to extract heat from the combustion process and the method used to exhaust the combustion gases. In these ways, the furnaces are very different. The condensing furnace does not have a significantly more efficient combustion process than does a conventional furnace; both use gas burners with electronic ignition. The difference lies in that the condensing furnace has a more efficient heat extraction process after combustion.
Many disconnect blocks contain two cartridge fuses. Check them before you proceed with repairs (Photo 3). A blown fuse is a sign of a failing part inside the condensing unit. So don’t just replace it and think you’ve solved the problem. Instead, replace the parts we show here. Then install new fuses and fire up the unit. If it blows again, call a pro—you’ve got more serious issues.
AC units and thermostats have built-in delay features when they’re shut down and then repowered. The delay can be as long as 10 minutes. And, if you’ve subscribed to an energy-saving device from your local power utility, the unit can take even longer to reset. If you’ve installed the parts shown and reinstalled the disconnect block, repowered the circuit breaker, turned on the switch at the furnace, moved the thermostat to AC mode and lowered the temperature below the indoor temperature, and the unit doesn’t fire up after 30 minutes, it’s time to call a pro.

Furnace Repair Co

×