If your furnace’s motor runs but the blower doesn’t move air, the belt that connects the two probably has broken. Replacing it is an easy fix. First, turn off all power to the unit and turn off the gas at the gas valve that serves the furnace. Remove the door on the front of the furnace cabinet to give you access to the blower (it might be on a slide-out drawer.) Check the number stamped on the belt and get an exact replacement from a home center or heating supply outlet.
You should also have air ducts cleaned after recent water contamination or water damage to prevent mold; after renovations or remodeling to ensure debris and dust didn’t settle in the vents and ducts; if you are having problems with allergies or asthma; or when you are moving into a newly purchased home, especially if the previous owners smoked or had pets. The National Air Duct Cleaners Association (NADCA) recommends getting your air ducts cleaned every three to five years, or every two to three years in regions where homeowners use their air conditioning and heater for many months of the year, while the EPA suggests homeowners have duct cleaning done as needed.
A pinging or popping sound coming from the duct work can come from thermal expansion—the ductwork expanding and contracting as it heats and cools.  Or, air blowing past a loose flap of metal can make the sound. Track along the duct runs, listening for the sound. If you locate it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.
With flexible financing options from Wells Fargo Financial National Bank, with approved credit, you can enjoy many benefits. From convenient monthly payments to easy-to-use online account management, Wells Fargo financing offers top notch service and control over your finances. We know you want to stay comfort without breaking the bank, so we help you manage your expenses. Call us at 303-678-5576 to learn more!

If your furnace has a pilot light, look for the flame. Check your owner’s manual or the instructions posted inside the furnace cabinet for step-by-step lighting instructions. Usually this involves first turning the gas valve to Off and waiting a couple of minutes. Then you turn it to Pilot. Next, press and hold it down while you light the flame. Last, wait a minute or so, release it, and then turn it to On.
You turn on your heating system because you have to. Many of our customers find cooling the home to be more natural than heating it. You certainly don’t look forward to that burst of unpleasant odor when you first turn on your heating system. Apart from unpleasant odors, you may also not look forward to the thin, dry, feel of the heated air that makes your nose dry and causes those irritating static shocks. Perhaps the heated air in your home never feels quite right. There’s just a hint of excess heat, but you don’t dare adjust the thermostat because then your home will feel too cold.
AC units and thermostats have built-in delay features when they’re shut down and then repowered. The delay can be as long as 10 minutes. And, if you’ve subscribed to an energy-saving device from your local power utility, the unit can take even longer to reset. If you’ve installed the parts shown and reinstalled the disconnect block, repowered the circuit breaker, turned on the switch at the furnace, moved the thermostat to AC mode and lowered the temperature below the indoor temperature, and the unit doesn’t fire up after 30 minutes, it’s time to call a pro.

Furnace Repair Co

×